- Flash point/moisture analyzer
The design and manufacture of this instrument comply with the requirements of methods such as ASTM D92 GB/T 267 and GB3536 "Determination of Flash Point and Ignition Point of Petroleum Products - Cleveland Open Cup Method". Suitable for petroleum products with an open cup flash point higher than 79 ℃, except for fuel oil. The instrument adopts AMD microprocessor technology, color touch screen, and Chinese English menu operation; The instrument has functions such as automatic ignition, flash point value display, detection and printing, and automatic cooling according to standard regulations; Accurate measurement, good repeatability, stable and reliable performance. Widely used in industries such as railway, aviation, power, petroleum, and scientific research for flash point and ignition point determination
1. Working power supply: AC220V ± 10%, 50Hz
2. Execution standard: GB/T3536-2008; GB/T267;ASTMD92;ISO2592
3. Display mode: Built in 8-inch color LCD display screen in both Chinese and English (resolution 1280X1024)
4. Operation method: Five wire resistor technology touch screen
5. Measurement range: Room temperature~430 ℃ Display accuracy 0.1 ℃
6. Temperature detection: NANMAC imported sensor from the United States
7. Flash fire sensor: ion detection ring
8. Flash point detection method: Built in millisecond level ultraviolet wavelength flash point detection device
9. Ignition method: Electric ignition
10. Cooling method: forced air cooling
11. Repeatability: ≤ 5 ℃
12. Reproducibility: ≤ 10 ℃, ignition point ≤ 8 ℃
13. Heating rate: required by GB/T3536 standard
14. Power: < 500W
15. Operating environment: Temperature range of 10 ℃ to 45 ℃,
16. Humidity 30-80%
17. Dimensions: 450 × 280 × 290mm
18. Weight: Approximately 15 kilograms
1. By adopting unique Peltier protection technology and automatic ignition cleaning program, the performance and lifespan of the temperature control device have been optimized, and the ignition device and testing accuracy have been efficiently protected.
2. Using high-precision processors imported from AMD, the PID control algorithm has high sensitivity and automatically adjusts the heating curve according to standards.
3. The entire experimental process of detection, lid opening, ignition, alarm, cooling, and printing is automatically completed.
4. Safe without gas source, platinum alloy electric heating wire ignition method, safe, stable, reliable, high testing accuracy.
5. Built in atmospheric pressure automatic detection chip, automatic measurement, calibration and correction of atmospheric pressure, and automatic correction of flash point value.
6. Differential detection, automatic correction of system deviation, automatic stop detection and alarm for temperature exceeding the limit.
7. Powerful storage function, capable of storing 500 measurement results for convenient historical queries.