    SC-3554 Petroleum Wax Oil Content Tester
    This instrument is designed and manufactured in accordance with the requirements specified in the Chinese standard GB/T3554 "Determination of Oil Content in Petroleum Wax". It is suitable for petroleum wax with a freezing point above 30 ℃ and an oil conte
    • Details
    • Parameter
    • characteristic

          This instrument is designed and manufactured in accordance with the requirements specified in the Chinese standard GB/T3554 "Determination of Oil Content in Petroleum Wax". It is suitable for petroleum wax with a freezing point above 30 ℃ and an oil content not exceeding 15%. For certain petroleum waxes with oil content greater than 5% that cannot be completely dissolved in butanone and stratify, this instrument is not suitable. Dissolve the sample in butanone solvent, and when the solution cools to -32 ℃, wax will precipitate. Remove the filtrate through a filter tube. And evaporate the solvent from the filtrate, weigh the residual oil, and calculate the mass fraction of oil content in the sample.

    1. Working power supply: AC220V ± 10% 50Hz;

    2. Water bath temperature: room temperature~100 ℃± 1 ℃

    3. Cold bath temperature: -35 ℃± 0.1 ℃;

    4. Evaporation temperature: 35 ℃± 1 ℃;

    5. Glass rotor flowmeter: (0-10) L/min;

    6. Timer timing range: (0-60) min.

    7. Cone weighing bottle capacity: 15mL~25mL

    8. Cooling time: ≤ 100min


    1. The cold bath is an independently designed refrigeration device (imported compressor refrigeration) with a total of 4 cold tanks, which can simultaneously test 4 samples.

    2. The cold bath and evaporator device are separated to avoid affecting the accuracy of the test during the operation of the refrigeration device.

    3. The evaporator at 35 ℃ is an air bath evaporation device, with a controlled temperature of 35 ℃. The blowing volume entering the sample in the evaporation device is detected by a glass rotor flowmeter, which can accurately control the blowing volume according to the specific requirements of the test. The blowing time can be set arbitrarily by a timer within 60 minutes according to the time requirements of the test.


    Related products

    Office Phone:+86 0731-85516578
    Fax:+86 0731-85535848
    Mobile phone:+86 139 7580 1381
    E-mail:cssc98@126.com
    Whatsapp/Wechat:24238498
    Address:Room 306, 3rd Floor, Building 4, No. 101, Hunan Provincial Research Achievement Transformation Center, Longping High tech Park, Furong District, Changsha City, Hunan Province

    Tiktok

    WeChat

    Video

    Mobile website

    Copyright (C) Changsha Sichen Instrument Technology Co., Ltd. 2024 All Rights Reserved

    在线客服系统

    MESSAGE

    Consultation Hotline:+86 400-660-9089
    Code