    SC-7534Z Automatic Boiling Range Tester
    This instrument is a third-generation product newly developed by our company, designed and manufactured according to the national standard GB/7534-2004 "Determination of Boiling Range of Volatile Organic Liquids for Industrial Use" standard test method. A
    • Details
    • Parameter
    • characteristic

            This instrument is a third-generation product newly developed by our company, designed and manufactured according to the national standard GB/7534-2004 "Determination of Boiling Range of Volatile Organic Liquids for Industrial Use" standard test method. At the same time, it can meet the national standard GB/T 615-2006 "General Method for Determination of Boiling Range of Chemical Reagents", integrating mechanical, optical, and electronic technologies, using imported sensors, and the liquid level reading of the measuring cylinder adopts an imported CNC optical tracking detection system. Automatic completion of the entire boiling process experiment, widely applicable to organic liquids with boiling points at atmospheric pressure (30-300 ℃) and chemical stability during distillation (such as hydrocarbons, esters, alcohols, ketones, ethers, and similar organic compounds), and can be customized with double tubes for conducting experiments on two different or identical samples simultaneously.

    1. Working power supply: AC220V ± 10% 50Hz 1.6KW

    2. Operation method: Windows operating system 10.4-inch color LCD touch screen

    3. Temperature range: 0-450 ℃, resolution 0.1 ℃, PT100 temperature sensor imported from Germany

    4. Refrigeration method: German imported compressor refrigeration

    5. Distillation rate: 2-10 mL/min (freely set, automatically adjusted)

    6. Volume detection range: 0-100mL resolution 0.1mL

    7. Cold bath temperature range: 0-80 ℃, temperature control accuracy of 0.2 ℃

    8. Cold trap temperature range: 0-60 ℃, temperature control accuracy of 0.2 ℃

    9. Pressure measurement range: 300-1100hPa, accuracy ± 3hPa, built-in pressure sensor, automatic value adjustment

    10. Safety protection system: Built in ultraviolet flame sensor for automatic monitoring, automatically opens the protective air valve when a flame occurs

    11. Protective gas interface: diameter 7.5-8mm; The protective gas is nitrogen or carbon dioxide, with a pressure not lower than 0.6Mpa

    12. Instrument dimensions: 460X500X660cm (length/width/height), net weight: approximately 70 kilograms

    13. Operating environment temperature: 5-40 ℃ Operating relative humidity: ≤ 80%


    1. The temperature of both the cold bath and the cold trap is controlled by a segmented program. The cold bath part adopts a metal bath technology that integrates condenser tubes and refrigeration evaporation tubes, ensuring direct conduction of cold and heat without liquid heat transfer medium, which is both safe and convenient

    2. The instrument adopts a lifting and self-locking lifting control technology, and the heating furnace can be quickly raised and lowered, and can be stopped at any position, truly realizing non-polar adjustment technology. At the end of the experiment, the furnace frame automatically slides down, cutting off the residual heat of the heat source and achieving rapid cooling

    3. The heating furnace adopts ceramic heating device pulse modulation infrared radiation heating method, with fast heating and cooling speed, ensuring safety and reliability

    4. The compressor, heating ceramic element, temperature sensor, and refrigeration diversion valve all use imported components to ensure the accuracy and reliability of instrument data, while also having a long service life and low failure rate

    5. The experimental data can be stored infinitely and viewed at any time. The built-in micro thermal printer outputs the detection results, which can also be exported through a USB flash drive to print data reports on a computer;

    6. Electric furnace cooling, after the experiment is completed, the cooling fan can automatically start and quickly cool down

    7. Infrared modulation optical technology realizes liquid level tracking detection and initial distillation detection, which is not affected by environmental interference, automatically detects the zero position of the volume, and can accurately determine the dry point

    8. Coated quartz orifice plate, heat-insulating and non explosive, easy to install orifice plate structure, no need to adjust when replacing orifice plates with different diameters


    Related products

    Office Phone:+86 0731-85516578
    Fax:+86 0731-85535848
    Mobile phone:+86 139 7580 1381
    E-mail:cssc98@126.com
    Whatsapp/Wechat:24238498
    Address:Room 306, 3rd Floor, Building 4, No. 101, Hunan Provincial Research Achievement Transformation Center, Longping High tech Park, Furong District, Changsha City, Hunan Province

    Tiktok

    WeChat

    Video

    Mobile website

    Copyright (C) Changsha Sichen Instrument Technology Co., Ltd. 2024 All Rights Reserved

    在线客服系统

    MESSAGE

    Consultation Hotline:+86 400-660-9089
    Code